by Kristen Sowatsky

In MDI Mode, enter: M59 P1133; G04 P1.0: M59 P1134.
  • In MDI Mode, enter: M59 P1133; G04 P1.0: M59 P1134.

  • With the doors open, press and hold CYCLE START.

  • After the program has run, gently tap the Tool Probe with your finger.

  • The control pendant will beep each time the Tool Probe is depressed. The Tool Probe is activated.

  • Press RESET to end the activation.

  • Make sure the screw is tight.

Hey there is something going on.

Richard - Reply

First, verify that the probe system and connections to the machine are functioning correctly.
  • First, verify that the probe system and connections to the machine are functioning correctly.

  • See step 3 and 4 for the correct process.

  • Please View wiring diagram

here is a comment!

Eric Doster - Reply

this is wrong, i do it differently.

Eric Doster - Reply

maybe this should be step 3

Richard - Reply

  • In MDI, enter: M59 P1134.

  • Hold the Work Probe within range of the OMI. Press and Hold CYCLE START.

  • Gently depress the stylus, the control pendant will beep indicating the prove is activated.

there was an error in this step - please refer to proper docs.

Eric Doster - Reply

  • Magnetic Base to mount the Indicator

  • "Calibration Bar", generally consisting of a 1/2" or 12 mm gauge pin clamped in a collet style toolholder.

  • "Ring Gauge" typcally with a 2.000" or 50.000 mm bore.

  • Test Indicator accurate to 0.0005" or 0.013 mm

Add Comment

  • This is how to adjust the runout of the Work Probe stylus.

  • First, Insert the Work Probe into the spindle.

  • Place the magnetic base on the table and align the indicator tip to the probe's stylus.

  • Jog the axes in 0.001 inch increments until the indicator touches the stylus.

  • With the indicator tip set against the stylus press E-STOP, so the probe isn’t accidentally ejected during adjustment.

Add Comment

  • Rotate the probe by hand to check runout.

  • If runout exceeds 0.0005" or 0.013 mm, adjustment is required.

  • Enter the runout reading.

  • tom

Add Comment

  • On the probe body, loosen the two upper LOCKING set screws slightly, and then lightly tighten them.

  • WARNING: The four lower sets of screws adjust the position of the stylus mount. Very small adjustments have a large effect on the stylus runout.

  • Decide which direction the stylus needs to be adjusted to reduce runout.

    • Loosen and then slightly tighten the two (2) opposing screws which are NOT inline with this direction to add some friction.

    • text

Add Comment

  • Gently loosen the second set of (2) opposite screws. These will be used to push the stylus mount into alignment.

  • Tighten the screw ON THE SAME SIDE as the highest indicator reading. This moves the stylus tip away from the indicator.

  • As you tighten the “pushing” screw you will need to loosen the opposite adjustment screw and locking screw slightly to allow movement.

Add Comment

  • Continue to adjust inward with each set of screws to reduce the runout as close to zero as possible.

  • When runout is below 0.0005" or 0.013 mm, carefully tighten each upper locking screw while at the same time tightening the opposite lower adjustment screw.

    • Then do the other set.

Add Comment

  • With the locking screws tight, check the runout at the stylus one more time.

  • Now that the work probe stylus is centered, calibration of both proves can begin.

  • This is the correct way to do this.

Add Comment

  • The WIPS Calibration Menus are explained in the Haas VMC Operator's Manual.

  • Press MDI/DNC.

  • Then Press PRGRM/CONVRS.

  • On the screen, select the SETUP tab.

  • Then select the TOOL PROBE CALIBRATION tab.

  • Insert the Calibration Bar into the spindle.

Add Comment

  • With the Indicator mounted on the table, measure the runout of the Calibration Bar gauge pin.

  • If runout exceeds 0.0005 inches or 0.013 mm the bar will need to be adjusted or replaced.

Add Comment

  • Using the Z-axis and an indicator, check the distance from the face of the spindle to the tip of the gauge pin.

  • This is NOT a Gauge Line measurement.

  • Use this method consistently to measure the Calibration Bar and the results will always be repeatable for quality work.

    • 1. GAUGE PIN FACE

    • 2. TOOL HOLDER GAUGE LINE

    • 3. SPINDLE FACE

Add Comment

  • Zero the indicator on the spindle face.

  • Then zero the Z-axis OPERATOR position on the screen.

  • Jog the Z-axis to bring the tip of the Calibration Bar to the same zero reading on the indicator.

Add Comment

  • Note the on-screen Z-axis value, this is your Calibration Bar length. Write this value on a piece of paper.

  • Test

Add Comment

  • Use a micrometer to find the diameter of the gauge pin used in the Calibration Bar and write this number down also.

  • Follow the on-screen prompts. Jogging Z-axis, bring the calibration bar just above the tool probe, and press F1.

  • Then Jog the X axis to center the bar over the tool probe and press F1 again. Do the same for the Y axis.

  • Next, enter the tool number you will use for the Calibration Bar.

Add Comment

  • Now enter the Calibration Bar length. Use the value you wrote down in Step 15.

  • Next, enter the micrometer reading previously noted in Step 16. WARNING: THIS MUST BE A DIAMETER AND NOT A RADIUS MEASUREMENT.

Add Comment

  • Press CYCLE START to execute the automatic calibration routine.

  • The Calibration Bar will touch off the top of the Tool Probe, and in four places on the side of the probe.

Add Comment

  • When the program is finished, the CALIBRATION status box will display COMPLETED. Calibration of the Work Probe can begin.

  • Press CANCEL and select the Work Probe Calibration tab.

  • Clamp the Ring Gauge to the table within reach of the probe. Enter the Work Offset to be used for Work Probe calibration.

  • link to a local file.

Add Comment

  • With the calibration bar in the spindle, position the pin above the edge of the ring gauge.

  • Place a shim, feeler gauge, or slip of paper over the gauge.

  • Press the .0001/.1 button. Jog the Z-axis so the tip of the bar slightly contacts the paper. Press F1.

  • Enter the length of the calibration bar from Step 15. Press the WRITE/ENTER button.

  • Enter the thickness of the shim used, in this case a piece of paper at 0.003 inch. Press WRITE/ENTER again.

Add Comment

  • Remove the calibration bar from the spindle and insert the Work Probe in its place.

  • Measure the Work Probe length with a machinist’s scale , (accuracy of 1/16 inch or 1.5 mm).

  • Note that the standard Renishaw probe uses a 0.2362 inch or 6 mm diameter ball.

  • Now enter the length of the Work Probe as well as the diameter of the indicating ball.

Add Comment

  • Measure the ring gauge with an inside micrometer or bore gauge. If the Inside Diameter is etched on the Gauge, that number can be used.

  • Next enter the diameter of the Ring Gauge and press WRITE/ENTER.

  • Jog the axes until the stylus tip is in the center of the ring, and about 0.3" or 7 mm above the surface.

Add Comment

  • Press CYCLE START to begin the automatic calibration process.

  • The Work Probe will touch the inside diameter of the ring gauge five separate times in X and Y.

  • Then, it touches off the top surface of the ring gauge.

Add Comment

  • This completes the calibration routine and the status box will display COMPLETED.

  • With the Work Probe runout set within specification and both Probes calibrated; the machine is ready to measure tools and work pieces using the WIPS probing routines.

Add Comment

Attached Documents

Kim Payne

Member since: 06/05/2014

797 Reputation

4 Guides authored

3 Comments

Guide was updated.

Brian Sallee - Reply

The work instructions were updated on 4/28/14. Step 2 was revised to include 2 new parts.

Brian Sallee - Reply

New Release: Please beware of changes.

Brian Sallee - Reply

Add Comment

View Statistics:

Past 24 Hours: 1

Past 7 Days: 22

Past 30 Days: 108

All Time: 4,942

CONFIDENTIAL - TRADE SECRET